کنترل دما و رطوبت
Temperature and humidity control module high precision digital display word double output automatic constant temperature and humidity control panel
Product Description
XY-WTH1 Temperature and humidity control module high precision digital display word double output automatic constant temperature and humidity control panel
Product adopts industrial-grade chip, high-precision SHT20 temperature and humidity sensor.
Product Function:
Product features are two main types of classification: the functions of temperature and humidity;
Function of temperature are as follows:
- The automatic identification of work mode:
The system automatically according to the start/stop temperature, identify work mode;
Start temperature > stop temperature, cooling mode'C'.
Start temperature < stop temperature, heating mode 'H'.
- Cooling mode:
When the temperature≥Start temperature,relay conduction,red led on, refrigeration equipment begin to work;
When the temperature≤Stop temperature,relay disconnect, red led off, refrigeration equipment stop to work;
- Heating mode:
When the temperature≤Start temperature,relay conduction, red led on, heating equipment begin to work;
When the temperature≥Stop temperature,relay disconnect, red led off, heating equipment stop to work;
- Temperature correction function OFE (-10.0 ~ 10℃):
The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value;
How to set the start/stop temperature:
1. In the running interface, Long Press ' TM+ ' key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM-key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ' TM-' key more than 3 seconds, into the stop temperature settings interface,can be modified by TM+ TM-key, to be modified after the parameters, waiting for 6s automatic exit and save;
The humidity function is as follows:
- The automatic identification of work mode:
The system automatically according to the start/stop humidity, identify work mode;
Start humidity> stop humidity, dehumidificationmode'D'.
Start humidity< stop humidity, humidificationmode 'E'.
- Dehumidificationmode:
When the humidity≥Start humidity,relay conduction, green led on, dehumidification equipment begin to work;
When the humidity≤Stophumidity,relay disconnect, green led off, dehumidificationequipment stop to work;
- Humidificationmode:
When the humidity≤Start humidity,relay conduction, green led on, humidificationequipment begin to work;
When the humidity≥Stophumidity,relay disconnect, green led off, humidificationequipment stop to work;
- Humidificationcorrection function RH (-10.0 ~ 10%):
The system is working for a long time and may be biased, through this function correction, the actual humidity= measuring humidity+ calibration value;
How to set the start/stop humidity:
1. In the running interface, Long Press ' RH+ ' key more than 3 seconds, into the start humiditysettings interface, can be modified by RH+ RH- key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ' RH-' key more than 3 seconds, into the stop humiditysettings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;
Running Interface Description:
Working mode shows that the current mode ("H/C", "E/d") will be synchronized at the front of temperature/humidity, when the setting of temperature/humidity and stop temperature/humidity are completed.
Any relay conduction, the upper-left corner of the interface display "out", if the temperature relay conduction, the flashing display temperature working mode "H/C" to show reminders; if the humidity relay conduction, then flashing display humidity working mode "E/d", as a reminder;
Other features:
- Parameter remote read/set:
Through the UART, set the starting temperature/humidity, stop temperature/humidity, temperature/humidity correction parameters;
- temperature/Humidity Real-time reporting:
If the temperature/humidity reporting function is turned on, the product will detect the temperature/humidity and relay status by the 1s interval, and pass the UART to the terminal to facilitate data collection;
- Relay enabling (by default):
If the relay is disable, the relay remains disconnected;
How to modify the temperature/humidity correction value:
- 1. In the operating interface, double-click the ' TM+ ' key to enter the correction of the set interface, the downward display correction of the type, the upward display of specific values; (OFE: Temperature correction value RH: Humidity correction value)
- At this time by a short press ' TM-' key, switch to modify the parameters, through the RH+ RH-key, modify the specific value of the support long press short;
3. When the parameters have been modified, double-click the ' TM+ ' key, exit the correction positive setting interface, and save the data;
How to enable/disable relay:
In the running interface, Short press ' TM-' key,enable/disablethe temperature relay(ON: enableOFF:disable), back to the running interface, if the temperature relay is disable, the temperature symbol ' ℃ ' flashes to remind.
In the running interface, Short press ' RH-' key, enable/disable the humidity relay (ON: enable OFF: disable), back to the running interface, if the humidity relay is disable, the humidity symbol '% ' flashes, as a reminder.
Serial control(TTL level)
BaudRate:9600bps Data bits :8
stop bits :1
crc :none
Flow control :none
CMD
|
Description
|
start
|
start data upload
|
stop
|
stop data upload
|
read
|
Read the param setting
|
T:ON
|
Temperature relay enable
|
T:OFF
|
Temperature relay disable
|
H:ON
|
Humidityrelay enable
|
H:OFF
|
Humidity relay disable
|
TS:XX.X
|
Set start Temperature
(-20.0~60.0)
|
TP:XX.X
|
Set stopTemperature
(-20.0~60.0)
|
HS:XX.X
|
Set start Humidity
(00.0~100.0)
|
HP:XX.X
|
Set stopHumidity
(00.0~100.0)
|
TC:XX.X
|
Set TemperatureCalibration
(-10.0~10.0)
|
HC:XX.X
|
Set HumidityCalibration
(-10.0~10.0)
|
Temperature and humidity Data upload format Description:
Temperature format: Operating mode (H/C), temperature value, temperature relay status;
Humidity Format: Operating mode (E/D), humidity value, humidity relay status;
H,20.5℃,CL:Heating operating mode, the current temperature of 20.5 degrees, temperature relay disconnection state;
D,50.4%,OP:Dehumidification working mode, current humidity 50.4%, humidity relay connection;